1.
Proj. Name:Oil
Mud Incinerator Off Gas Emission Improvement Project
2.
Client:CPC
Tao-yuan Refinery
3.
Proj. Period:May
2018∼Oct..
2019
4. Proj. Description:
The
purpose of this Project is for the improvement of off gas emission from
existing CPCT rotary kiln to meet local EPA requirement due to higher
sulphur content in oil mud fed, which is over the original design condition
and could result in a higher SOx
emission happened. After the new
scrubbing system of facilities installed, the off gas SO2
emission can be extremely reduced and also the odor smell can be improved
obviously; therefore, a much better environmental air quality can be gained.
It is expected that in the off gas inlet conditions with 0.2 Vol%
high SO2 concentration at gas flow rate of 12,000 Nm3/hr (max.)
the off gas would be scrubbed by NaOH caustic soda solution, and the SO2
concentration of emission outlet could be decreased to
≦50ppmv
with COD of effluent
≦900
mg/L.
5. Major construction item:
◆
Reverse Jet Scrubber x 1 Unit
(Incl. 316L
Absorption Vessel, Duplex 2205 Inlet Barrel,
8” SiC
Reverse jet
Nozzles, Froth Zone、Chevron
Demister……etc.).
◆
Scrubber Circulation Pump x 2 sets,
Liquid Caustic Pump x 2 sets, Effluent Pump x 2 sets,
Oxidation
Blower x 2 sets.
◆
Counter Flow Cooling Tower x 1 set.
◆
FRP
Liquid NaOH Tank x 1
set.
◆
316L Oxidation Liquid Tank (Incl.
internal air spargers) x 1 set.
◆
Renew Existing I.D. Fan (Incl.
Inverter Motor) x 1 set, Replace Some of Biger Diameter
Inlet/Outlet
Flue Gas
Piping of I.D. Fan .
◆
Process & Utility Piping System
w/different kinds of Material, Effluent Wastewater Piping.
◆
Civil Foundation, Operation Platform,
Dike and Acquisition of Government Permits and
Construction
License Aapplication.
◆
Instruments Incl. Control Valves,
Ultrasonic Liquid L/T, D/P Flowmeter, D/P Density
Transmitter, PH
Analyzer,
and Thermometer/ Pressure Gauge, etc.
◆
Power Equipment Incl. MCC Panel, Site Explosion-proof Lighting Fixture,
Grounding,
Communication, Power Cable and
Conduit, Site Switching Station.
|